Chart of Cable Spacing



Engineering Data On Cable Pass-Through


Chart for Section B - Wire Rope Cable Intermediate Rail Pass-through Resistance to 4" Sphere

This chart was prepared by The Cable Connection to summarize the calculations in Section B (Pass-through resistance to 4" sphere) based on 400 pounds of tension on each cable.

For engineering calculations on a particular diameter cable go to: Section B - Calculations for various cable diameters.

Cable Diameter Center-To-Center Spacing on End Post Anchor
(End Post)
Spacing
Cable Support Spacing Cable Spread with 4" Sphere Load Applied as Required by 2006 IRC and IBC Codes
1/8" 3.10" 50 Ft. 42" 3.474"
3/16"
3/16"
3.10"
3.25"
50 Ft.
50 Ft.
42"
42"
3.439"
3.699"
1/4"
1/4"
3.10"
3.36"
50 Ft.
50 Ft.
42"
42"
3.405"
3.880"
5/16"
5/16"
5/16"
3.10"
3.25"
3.36"
50 Ft.
50 Ft.
50 Ft.
42"
42"
42"
3.368"
3.567"
3.735"
3/8"
3/8"
3/8"
3.10"
3.25"
3.36"
50 Ft.
50 Ft.
50 Ft.
42"
42"
42"
3.328"
3.513"
3.659"
Carson City, Nevada - U.S.A.
1-800-851-2961
info@ultra-tec.com
Copyright 2010 The Cable Connection, Carson City, Nevada. All rights reserved. Limited copies permitted for instructional and product specification purposes only. Drawings may be downloaded and used on projects using products offered by the Cable Connection.