Chart of Cable Spacing
Engineering Data On Cable Pass-Through
Chart for Section B - Wire Rope Cable Intermediate Rail Pass-through Resistance to 4" SphereThis chart was prepared by The Cable Connection to summarize the calculations in Section B (Pass-through resistance to 4" sphere) based on 400 pounds of tension on each cable.
For engineering calculations on a particular diameter cable go to:
Section B - Calculations for various cable diameters.
| Cable Diameter |
Center-To-Center Spacing on End Post |
Anchor (End Post) Spacing |
Cable Support Spacing |
Cable Spread with 4" Sphere Load Applied as Required by 2006 IRC and IBC Codes |
| 1/8" |
3.10" |
50 Ft. |
42" |
3.474" |
3/16" 3/16" |
3.10" 3.25" |
50 Ft. 50 Ft. |
42" 42" |
3.439" 3.699" |
1/4" 1/4" |
3.10" 3.36" |
50 Ft. 50 Ft. |
42" 42" |
3.405" 3.880" |
5/16" 5/16" 5/16" |
3.10" 3.25" 3.36" |
50 Ft. 50 Ft. 50 Ft. |
42" 42" 42" |
3.368" 3.567" 3.735" |
3/8" 3/8" 3/8" |
3.10" 3.25" 3.36" |
50 Ft. 50 Ft. 50 Ft. |
42" 42" 42" |
3.328" 3.513" 3.659" |